Pre-Installation Setup > Prerequisites for Adding Data Collectors
   
Version 9.1
Prerequisites for Adding Data Collectors
64-bit OS. See the APTARE StorageConsole 9.1 Certified Configurations Guide for supported operating systems.
Support Java Runtime Environment (JRE) 1.7.
Reside in the same time zone as the subsystem from which data will be collected.
For performance reasons, APTARE recommends that you do not install Data Collectors on the same server as the StorageConsole Portal. However, if you must have both on the same server, verify that the Portal and Data Collector software do not reside in the same directory.
Install only one Data Collector on a server (or OS instance).
Storage Array Prerequisites
Before you install Data Collectors, refer to the individual array vendors for additional specific prerequisites.
Adding a Dell Compellent Data Collector Policy
Adding an EMC Isilon Data Collector Policy
Adding an EMC Symmetrix Data Collector Policy
Adding an EMC VNX (Celerra) Data Collector Policy
Adding an EMC VNX (CLARiiON) Data Collector Policy
Adding a Hitachi Block Storage Data Collector Policy
Adding a Hitachi NAS (HNAS) Data Collector Policy
Adding an HP 3PAR Data Collector Policy
Adding an HP EVA Data Collector Policy
Adding an IBM Modular Array Data Collector Policy
Adding an IBM Enterprise Array Data Collector Policy
Adding an IBM SVC Data Collector Policy
Adding an IBM VIO Data Collector Policy
Adding an IBM XIV Data Collector Policy
Adding a NetApp Data Collector Policy
Host Resource Prerequisites
For specific prerequisites, refer to Host Resources Prerequisites and Configurations.
 
Array Performance Data Collection Prerequisites
The following table lists the Array Families from which performance data can be collected and reported.
LUN Performance Statistics
Array Family
Read/Write IO/sec
Total
IO/sec
Read/Write
MB/sec
Read/Write Cache Hits/sec
Read/Write Response (ms)
Total Response (ms)
Dell Compellent
X
X
X
X
Calculated
Calculated
EMC VNX (CLARiiON) 1
X
Calculated
X
X
X
Calculated
EMC Symmetrix 2
X
X
X
X
Calculated
Calculated
HDS Tuning Manager 3
X
Calculated
X
X
X
X
HP 3PAR
X
X
X
X
Calculated
Calculated
IBM SVC
X
X
X
--
--
--
IBM XIV
X
X
X
X
X
X
NetApp ONTAP (Block only) 4
X
Calculated
X
--
--
Avg Latency
1 For CLARiiON arrays: The minimum FLARE OS version required to capture response times is 04.30.000.5.524 A11. Note that VNX (Block) will have completely different FLARE releases and all support the collection of the counter fields needed for capturing response time, starting with FLARE version 05.31.000.5.006 A01.
2 For Symmetrix arrays: The response times are estimated only. Also, for LUNs with low I/O rates, the estimation may be higher than the actual response times experienced.
3 For Hitachi arrays: To collect performance data from Hitachi Tuning Manager, the Data Collector must be installed on the same server as Tuning Manager. And, a single Data Collector policy must be used to collect both the capacity data from the Device Manager server and the performance data from the Tuning Manager server.
4 For NetApp ONTAP (Block only): Total response time is the average latency (ms) for all LUN read and write operations. Performance data is collected for both iSCSI LUNs and FC LUNs.
5 For Dell Compellent: Only Fibre Channel port statistics are collected.
Port Performance Statistics
Array Family
Read/Write MB
Total MB
Read/Write I/O
Total I/O
Dell Compellent 5
X
Calculated
--
X
EMC VNX (CLARiiON)
------------------------------- Not Supported -----------------------------------
EMC Symmetrix
--
X
--
X
HDS Tuning Manager
X
X
X
X
HP 3PAR
X
Calculated
--
X
IBM SVC
------------------------------- Not Supported -----------------------------------
IBM XIV
X
X
X
X
NetApp ONTAP (Block only)
X
Calculated
--
--
Calculated = Calculated from collected data, X = Collected from the array, -- = Not Collected