EMC Symmetrix - Planning the Data Collector Deployment
  
Version 9.2.00
For details, refer to the APTARE StorageConsole Certified Configurations Guide and the APTARE StorageConsole Data Collector Installation Guide for Capacity Manager.
EMC Symmetrix - Planning the Data Collector Deployment
1. Identify a server where the Data Collector software will be installed. Server requirements include:
64-bit OS. See the APTARE StorageConsole Certified Configurations Guide for supported operating systems.
Support Java Runtime Environment (JRE) 1.7.
Reside in the same time zone as the subsystem from which data will be collected.
If the backup servers belong to a cluster, StorageConsole communicates with the cluster for data collection.
For performance reasons, APTARE recommends that you do not install Data Collectors on the same server as the StorageConsole Portal. However, if you must have both on the same server, verify that the Portal and Data Collector software do not reside in the same directory.
Install only one Data Collector on a server (or OS instance).
2. On the Data Collector server, add entries to the local hosts file, both resolving to the Portal server IP address.
 
Example:
172.16.2.2 aptareportal.<yourdomain>.com
172.16.2.3 aptareagent.<yourdomain>.com
Data Collector Configuration Specific to EMC Symmetrix
 
1. Note the port used by the EMC Symmetrix Data Collector: Port 2707 to the Solutions Enabler host.
2. Data Collector must be installed on the server that manages the Symmetrix array with SymCLI installed on this server.
3. Recommended: EMC Solutions Enabler should be running on a server that is not the Data Collector server with the SYMAPI server daemon (storsrvd) running on this server. See the APTARE StorageConsole Data Collector Installation Guide for Capacity Manager for steps to verify this configuration.
4. Set the EMC Solutions Enabler user account to StorageAdmin instead of Monitor.
5. Gather the following required configuration details:
SYMAPI Service Names: Defined in $EMC_HOME\SYMAPI\config\netcnfg of the Data Collector server.
Symmetrix Client Software Location: Path to the software on the Data Collector.
6. Configure a Data Collector policy using the following additional details.
Field
Description
Domain
Typically, only one domain is listed; Managed Services Providers will have a domain for each customer.
SYMAPI Service Names
Comma-separated list of SYMAPI service names, which are defined in $EMC_HOME\SYMAPI\config\netcnfg of the Data Collector server. Typically, $EMC_HOME on Windows is C:\Program Files\EMC and on UNIX it is /usr/
EMC Symmetrix Client Software Location
This location refers to the location on the Data Collector.
Linux: /usr/symcli/bin
Windows
: C:\Program Files\EMC\symCLI\bin.
Arrays to Exclude
List Symmetrix SymIDs to be excluded from collection.
Array Details
Click the check box to activate array details collection.
Array Performance
Click the check box to activate array performance collection.
7. On the Data Collector server, install/update the Data Collector software, using the instructions in the APTARE StorageConsole Data Collector Installation Guide for Capacity Manager.