1. Identify a server where the Data Collector software will be installed. Server requirements include:
64-bit OS.
Support Java Runtime Environment (JRE) 1.7.
For performance reasons, APTARE recommends that you do not install Data Collectors on the same server as the StorageConsole Portal. However, if you must have both on the same server, verify that the Portal and Data Collector software do not reside in the same directory.
Install only one Data Collector on a server (or OS instance).
2. On the Data Collector server, add entries to the local hosts file, both resolving to the Portal server IP address.
 
Example:
172.16.2.2 aptareportal.<yourdomain>.com
172.16.2.3 aptareagent.<yourdomain>.com
Data Collector Configuration Specific to EMC Symmetrix
 
1. Data Collector must be installed on the server that manages the Symmetrix array with SymCLI installed on this server.
Recommended: EMC Solutions Enabler should be running on a server that is not the Data Collector server with the SYMAPI server daemon (storsrvd) running on this server.
2. Set the EMC Solutions Enabler user account to StorageAdmin instead of Monitor.
Gather the following required configuration details:
SYMAPI Service Names: Defined in $EMC_HOME\SYMAPI\config\netcnfg of the Data Collector server.
Symmetrix Client Software Location: Path to the software on the Data Collector.
3. Configure a Data Collector policy using the following additional details.
Field
Description
Domain
Typically, only one domain is listed; Managed Services Providers will have a domain for each customer.
SYMAPI Service Names
Comma-separated list of SYMAPI service names, which are defined in $EMC_HOME\SYMAPI\config\netcnfg of the Data Collector server. Typically, $EMC_HOME on Windows is C:\Program Files\EMC and on UNIX it is /usr/
EMC Symmetrix Client Software Location
This location refers to the location on the Data Collector.
Linux: /usr/symcli/bin
Windows
: C:\Program Files\EMC\symCLI\bin.
Arrays to Exclude
List Symmetrix SymIDs to be excluded from collection.
Array Details
Click the check box to activate array details collection.
Array Performance
Click the check box to activate array performance collection.