Array Capacity Utilization Reports > Hitachi NAS System Drive Summary
  
Version 10.2.01P10
Hitachi NAS System Drive Summary
Explore your data center using APTARE customizable report templates or by using parts of your IT infrastructure as entry points. Use Search to find reports, templates and dashboards across the portal.
Use the Reports tab to examine the catalog of templates, dashboards and reports - organized by products along with user-created, and system folders. This report is located here:
This report lists all of the Hitachi NAS (HNAS) System Drives (SD) configured as of the last data collection cycle. There will be a line item for each SD in the scope of the report. Multiple filers are possible. System Drives are special drives required in each Cluster for internal purposes only.
Storage Array
The name given to the storage array.
Label
HNAS system drive number assigned by the server to uniquely identify the system drive.
Status
The system drive's status on the cluster node, as reported by the SCSI driver.
Role
The system drive's mirror role: primary or secondary. If relevant, this will also include the system drive to which this one is mirrored, according to the configuration of the span that includes the system drives. If the system drive has been pegged, the role will be also be shown. Example: Secondary (Scsi: Primary; peg Secondary); configured partner: 3, where Secondary is the effective role, Primary is the role reported by the RAID controller to the servers SCSI driver, and in this case, the system drive's role has been pegged to Secondary.
Access
HNAS system drive access status. Allowed = access to the system drive is allowed, otherwise the value is set to Denied.
Storage Pool
The name that was assigned to the span when it was created.
SD Group
List of all the system drives that are in the same group as this HNAS system drive. This value will be None if the system drive is not in a group.
Capacity
Total capacity of the HNAS physical disk. Values are stored in the database as KiB and rendered according to your user profile preferences.
Manf
Manufacturer of the HNAS physical disk.
Comment/Rank Name
User-assigned comment for the HNAS system drive.
Disk Type
Type of HNAS physical disk.
Disk Size
Total capacity of the HNAS system drive. Values are stored in the database as KiB and rendered according to your user profile preferences.
Superflush
The number of data disks in the system drive, and the RAID5 stripe size. The server uses these details to optimize write operations. Super flush aggregates I/O and is used to improve write performance.
Chunk Size
The number of bytes in an HNAS system drive data block.
Tier
Name of the HNAS tier.
LUN
The logical unit number (LUN) used by the RAID controller to identify a system drive. Within a single RAID rack, every system drive will have a unique LUN. Since a single server can communicate with multiple RAID racks, several system drives can have the same LUN.For Hitachi Data Systems storage, this is the external (host) LUN and the internal LUN is <>.
Site
Site ID that an administrator has assigned to the HNAS system drive.
Serial #
System Drive's serial number, as taken from the SCSI standard inquiry.