Storage Performance Reports > Capacity Manager Array Performance Metrics
  
Version 10.1.01
Capacity Manager Array Performance Metrics
 
The following array families are supported for block storage LUN performance and port performance data collection.
LUN Performance Metrics
Array Family
Read/Write IO/sec
Total IO/sec
Read/Write
MB/sec
Read/Write Cache Hits/sec
Read/Write Response (ms)
Total Response (ms)
Dell Compellent
X
X
X
X
--
--
EMC VNX (CLARiiON) 1
X
Calculated
X
X
X
Calculated
EMC Symmetrix
X
X
X
X
--
--
HDS Tuning Manager 2
X
Calculated
X
X
X
X
HP 3PAR
X
X
X
X
X
X
IBM SVC
X
X
X
--
--
--
IBM XIV
X
X
X
X
X
X
NetApp ONTAP 7-Mode (Block only) 3
X
Calculated
X
--
--
Avg Latency
Pure Storage FlashArray
X
Calculated
X
--
X
Calculated

1 For CLARiiON arrays: The minimum FLARE OS version required to capture response times is 04.30.000.5.524 A11. Note that VNX (Block) will have completely different FLARE releases and all support the collection of the counter fields needed for capturing response time, starting with FLARE version 05.31.000.5.006 A01. Enable statistics logging on the VNX system.

2 For Hitachi arrays: To collect performance data from Hitachi Tuning Manager, the Data Collector must be installed on the same server as Tuning Manager. And, a single Data Collector policy must be used to collect both the capacity data from the Device Manager server and the performance data from the Tuning Manager server.

3 For NetApp ONTAP 7-Mode (Block only): Total response time is the average latency (ms) for all LUN read and write operations. Performance data is collected for both iSCSI LUNs and FC LUNs.

Port Performance Metrics
Array Family
Read/Write MB
Total MB
Read/Write I/O
Total I/O
Dell Compellent 1
X
Calculated
--
X
EMC VNX (CLARiiON)
Not Supported
Not Supported
Not Supported
Not Supported
EMC Symmetrix
--
X
--
X
HDS Tuning Manager
X
X
X
X
HP 3PAR
X
Calculated
--
X
IBM SVC
Not Supported
Not Supported
Not Supported
Not Supported
IBM XIV
X
X
X
X
NetApp ONTAP 7-Mode (Block only)
X
Calculated
--
--

1 For Dell Compellent: Only Fibre Channel port statistics are collected.

Calculated = Calculated from collected data, X = Collected from the array, -- = Not Collected
 
EMC Isilon Metrics
Isilon performance data (raw, hourly, and daily) is collected from SNMP MIB statistics. For example, collected data includes such metrics as cluster, node, protocols (CIFS, SMB, FTP, HTTP), and disk performance. See the Array Performance Statistics Technical Note for an extensive list of collected metrics.
NetApp Cluster-Mode Metrics
A large variety of NetApp Cluster-Mode performance data (raw, hourly, and daily) is collected. For example, collected data includes such metrics as system, protocols (CIFS and NFS), volume, LUN, and target port performance. See the Array Performance Statistics Technical Note for an extensive list of collected metrics.
EMC Symmetrix Enhanced Performance Metrics
In addition to LUN and Port performance metrics that can be collected from EMC Symmetrix arrays, data collection gathers other performance metrics by accessing storage devices via the EMC Unisphere REST API. See the Array Performance Statistics Technical Note for an extensive list of collected metrics.