Hitachi NAS - Planning the Data Collector Deployment
  
Version 10.0.00
For details, refer to the APTARE StorageConsole Certified Configurations Guide and the APTARE StorageConsole Data Collector Installation Guide for Capacity Manager.
Hitachi NAS - Planning the Data Collector Deployment
1. Identify a server where the Data Collector software will be installed. Server requirements include:
Support Java Runtime Environment (JRE) 1.7
Reside in the same time zone as the subsystem from which data will be collected
For performance reasons, APTARE StorageConsole Data Collectors should not be installed on the same server as the StorageConsole Portal. If, for some reason, you require both to be on the same server, the Portal and Data Collector software should not reside in the same directory on the server.
2. On the Data Collector server, add entries to the local hosts file, both resolving to the Portal server IP address.
 
Example:
172.16.2.2 aptareportal.<yourdomain>.com
172.16.2.3 aptareagent.<yourdomain>.com
Data Collector Configurations Specific to Hitachi NAS
If collecting performance data, the Data Collector must be installed on the same server as HTnM (Tuning Manager). And, a single Data Collector policy must be used to collect both the capacity data from the Device Manager server and the performance data from the Tuning Manager server.
Gather the following required configuration details:
HNAS Admin EVS Address
User ID & Password: Credentials with supervisor privileges for accessing the Hitachi NAS.
Server Control (SSC) Utility Location: Location of the SSC command-line utility.
1. Configure a Data Collector policy using the following additional details.
Field
Description
Collector Domain
The domain of the collector to which the collector backup policy is being added.Typically, only one domain is listed; Managed Services Providers will have a domain for each customer.
Policy Domain
The Policy Domain is the domain of the policy that is being configured for the Data Collector.
HNAS Admin EVS Addresses*
Enter one or more Hitachi NAS Admin EVS addresses separated by commas.
Note: You must also create a separate Data Collector policy to collect the block storage that shares the space with Hitachi NAS (HNAS). Choose a relevant supported storage vendor policy such as Hitachi Block Storage.
Server Control (SSC) Utility Location
The location of the SSC command-line utility.
Linux: /usr/bin/ssc
Windows: c:\program files\ssc
User ID & Password
Create a user with supervisor privileges for accessing the Hitachi NAS.
Array Details
Click the clock icon to create a schedule.
2. On the Data Collector server, install/update the Data Collector software, using the instructions in the APTARE StorageConsole Data Collector Installation Guide for Capacity Manager.