Pre-Installation Setup for Brocade Switch > Brocade Switch Data Collector Policy
  
Version 10.0.01
Brocade Switch Data Collector Policy
Before adding the policy: A Data Collector must exist in the Portal, to which you will add Data Collector Policies. See Adding/Editing Data Collectors. For specific prerequisites and supported configurations, see Prerequisites for Adding Data Collectors (Brocade Switch) and the APTARE StorageConsole Certified Configurations Guide.
1. Select a Data Collector from the list.
2. Click Add and select Brocade Switch.
Best Practices: Interconnected switches should be configured in the same Data Collector policy.
3. Enter or select the parameters. Mandatory parameters are denoted by an asterisk (*):
Field
Description
Sample Value
Collector Domain
The domain of the collector to which the collector backup policy is being added. This is a read-only field. By default, the domain for a new policy will be the same as the domain for the collector. This field is set when you add a collector.
 
Policy Domain
The Collector Domain is the domain that was supplied during the Data Collector installation process. The Policy Domain is the domain of the policy that is being configured for the Data Collector. The Policy Domain must be set to the same value as the Collector Domain.
The domain identifies the top level of your host group hierarchy. All newly discovered hosts are added to the root host group associated with the Policy Domain.
Typically, only one Policy Domain will be available in the drop-down list. If you are a Managed Services Provider, each of your customers will have a unique domain with its own host group hierarchy.
To find your Domain name select Admin > Hosts and Domains > Domains.
yourdomain
Brocade SMI agent address*
Enter the IP address of the Brocade SMI agent and port number in the format: <ip_address>:port_number The port number is NOT required if you want to use the default port numbers: 5988 (http) or 5989 (https).
192.1.1.1
User ID*
Use the User ID and passcode for accessing the switch. This typically would be an administrator privilege, but must be a minimum privilege of a view-only user.
Administrator
Password*
Note: The password is encrypted prior to saving in the database and is never visible in any part of the application.
Password1
Exclude Switches
Enter a switch WWN - e.g., 10:00:00:60:69:90:04:9F, 100000606990049F
Colons within the WWN are NOT required. A comma-separated list is supported.
10:00:00:60:69:90:04:9F, 100000606990049F
Switch Details
Click the check box to collect switch details.
Click the clock icon to create a schedule. Every Minute, Hourly, Daily, Weekly, and Monthly schedules may be created. Advanced use of native CRON strings is also available.
Examples of CRON expressions:
*/30 * * * * means every 30 minutes
*/20 9-18 * * * means every 20 minutes between the hours of 9am and 6pm
*/10 * * * 1-5 means every 10 minutes Mon - Fri.
Note: Explicit schedules set for a Collector policy are relative to the time on the Collector server. Schedules with frequencies are relative to the time that the Data Collector was restarted.
 
FC Port statistics Active
Click the check box to collect FC Port statistics. This may have a performance impact, which can be optimized with the FC Port statistics schedule.
Click the clock icon to create a schedule.